Indexing metadata

PENGARUH PLUGGING TUBE TERHADAP KINERJA KONDENSOR ST1.0 BLOK 1 PLTGU MUARA KARANG


 
Dublin Core PKP Metadata Items Metadata for this Document
 
1. Title Title of document PENGARUH PLUGGING TUBE TERHADAP KINERJA KONDENSOR ST1.0 BLOK 1 PLTGU MUARA KARANG
 
2. Creator Author's name, affiliation, country Siti Khoiriyah; <span>Program Studi Teknik Konversi Energi, Jurusan Teknik Mesin, Politeknik Negeri Jakarta</span>; Indonesia
 
2. Creator Author's name, affiliation, country Fatkhiya Mukarromah; Program Studi Teknik Konversi Energi, Jurusan Teknik Mesin, Politeknik Negeri Jakarta
 
2. Creator Author's name, affiliation, country Elfi Nur Rohmah; Program Studi Teknik Konversi Energi, Jurusan Teknik Mesin, Politeknik Negeri Jakarta
 
2. Creator Author's name, affiliation, country Fachrudin Fachrudin; Program Studi Teknik Konversi Energi, Jurusan Teknik Mesin, Politeknik Negeri Jakarta
 
3. Subject Discipline(s)
 
3. Subject Keyword(s) Condenser; Crossflow; Tube; Percentage of Plugging; Performance decrease
 
4. Description Abstract Condenser in Steam power plant Block 1 Muara Karang with Surface Condenser type and Water Cooled system, Crossflow with 1 mixed fluid (steam) and other fluid is unmixed (cooling water),water cooled flowing in the tube and steam crossflow directly. Condenser tube often have problems, that is leakage caused by corrosion, bend and dents due to poor heat transfer, even blockage due to marine biota. If there is a leak in the tube, that could cause the risk of sea water in the tube will contaminate the water condensate in hotwell, the result of condensation of the vapor. If contaminated water contents, will damage the components especially in HRSG. To overcome the leaks that occur on the tube then we have to do Plugging,that is the closure of the inlet side and outlet side tube, so that the water doesn't go through the tube. However, due to Plugging, the performance of the condenser is decreased because the surface area for heat transfer is reduced. Therefore, it is important for the amount possibility of Plugging on the condenser tube to keep the condenser performance safe. Condensor performance analysis based on 3 aspect, Effectivenes, Vacuum Pressure, and cooling water flow. The NTU method is used as the effectiveness formula in this study. From the calculations and analysis, it is found that the decrease in effectiveness occurs linearly, where each 5% increase in Plugging occurs average decrease about 2.09% effectiveness at load 3 HRSG (+/- 150 MW), 2.43% decrease effectiveness at load 2 HRSG (+/- 100 MW), and 2.59% decrease effectiveness at load 1 HRSG (+/- 50 MW). Analysis of vacuum condensor obtained Plugging limit is 25.21%.However, based on calculation of the effect of Plugging on the cooling water flow rate, it can be conclude the permitted Plugging is 15% at load 3 HRSG, and 20% at load 2 and 1 HRSG
 
5. Publisher Organizing agency, location
 
6. Contributor Sponsor(s)
 
7. Date (YYYY-MM-DD) 2019-01-16
 
8. Type Status & genre Peer-reviewed Paper
 
8. Type Type
 
9. Format File format PDF
 
10. Identifier Universal Resource Indicator http://semnas.mesin.pnj.ac.id/seminar/index.php/semnas/SNTM18/paper/view/45
 
11. Source Journal/conference title; vol., no. (year) Seminar Nasional Teknik Mesin; Seminar Nasional Teknik Mesin 2018
 
12. Language English=en id
 
13. Relation Supp. Files
 
14. Coverage Geo-spatial location, chronological period, research sample (gender, age, etc.)
 
15. Rights Copyright and permissions Authors who submit to this conference agree to the following terms:
a) Authors retain copyright over their work, while allowing the conference to place this unpublished work under a Creative Commons Attribution License, which allows others to freely access, use, and share the work, with an acknowledgement of the work's authorship and its initial presentation at this conference.
b) Authors are able to waive the terms of the CC license and enter into separate, additional contractual arrangements for the non-exclusive distribution and subsequent publication of this work (e.g., publish a revised version in a journal, post it to an institutional repository or publish it in a book), with an acknowledgement of its initial presentation at this conference.
c) In addition, authors are encouraged to post and share their work online (e.g., in institutional repositories or on their website) at any point before and after the conference.